Maestro and Desmond
The purpose of this documentation is to introduce the Desmond molecular dynamics simulation environment available through the graphical user interface of Schrödinger Maestro.
The guide presents the most common workflows through practical examples, covering the entire process from system preparation and simulation setup to running simulations and analyzing the results.
In this chapter, we demonstrate the complete workflow of a molecular dynamics simulation of a protein-ligand complex.
Typical workflow steps:
Importing a structure (typically a protein or nucleic acid)
Running the Protein Preparation Workflow
Building the simulation system
Relaxation
Running the molecular dynamics simulation
Trajectory analysis
Note
For beginner users, it is recommended to first follow the complete workflow using the default settings.
Workflow overview:
Biomolecular Structure
↓
Protein Preparation Workflow
↓
System Builder
↓
Relaxation
↓
Production MD
↓
Analysis
In this example, we demonstrate the preparation, solvation, and a 25 ns molecular dynamics simulation of the 1RDE structure using the Maestro and Desmond software packages.
The aim of this tutorial is to present a complete workflow, from downloading structural data to RMSD evaluation.
For this example, we use a thrombin-binding DNA aptamer, a single-stranded 15-nucleotide DNA aptamer whose structure was determined by solution NMR. The PDB identifier of the structure is 1RDE. According to the PDB entry, the structure consists of an NMR ensemble containing 11 conformers. In the following examples, the first model of the ensemble will be used.
The input file with the .pdb extension can be obtained from the PDB database (https://www.rcsb.org/) or downloaded directly to the desired directory using the following command:
wget https://files.rcsb.org/download/1RDE.pdb
To open the downloaded structure, start Maestro and select:
File
└── Import Structures...
Alternatively, simply drag and drop the
1RDE.pdb file into the Maestro window.
After loading the structure, the NMR-derived structural ensemble appears in the Workspace window. The PDB file contains a total of 11 models.
The models can be viewed in the Project Table window.
Note
NMR structures often contain multiple conformers. In this example, only the first model will be used for all subsequent calculations.
After selecting the first model, it is recommended to remove the remaining conformers to avoid potential issues later in the workflow.
Once the first model of the NMR ensemble has been selected, the other entries can be removed from the Entries panel so that all subsequent calculations are performed only on the first conformer.
Protein Preparation Workflow
Structures obtained from the PDB database are generally not suitable for direct use in molecular dynamics simulations. Maestro therefore provides a preprocessing workflow that checks the structure, adds missing atoms, and optimizes the hydrogen-bond network.
The module can be started from the following menu:
Workflows
└── Prepare
└── Protein Preparation Workflow
The dialog window contains four main steps:
Specify Protein
Preprocess
Optimize H-bond Assignments
Minimize and Delete Waters
Specify Protein
The starting structure can be selected from the current contents of the Workspace.
In the present example, the first NMR model is already loaded in the Workspace; therefore, the following setting is appropriate:
Use structures from:
Workspace (included entry)
A detailed inspection of the structure can be performed using the Review Structure option.
Preprocess
The Preprocess step automatically performs the initial preparation of the structure. In most cases, the default settings are sufficient.
During this procedure:
hydrogen atoms are added;
chemical bonds are checked;
potential structural issues can be corrected;
a force field-compatible model is generated.
For nucleic acid systems, it is advisable to verify that the phosphate groups and nucleobases have been correctly identified.
Optimize H-bond Assignments
In this step, the program optimizes the positions of hydrogen atoms involved in hydrogen bonding.
The algorithm considers potential donor and acceptor sites and, when necessary, adjusts the orientation of hydrogen atoms to establish a more energetically favorable hydrogen-bond network.
In this example, the default settings can be used.
Minimize and Delete Waters
In the final step, a restrained energy minimization is performed on the structure.
Since the 1RDE NMR structure does not contain crystallographic water molecules, the water deletion options are not particularly relevant in this example.
The purpose of the minimization is to reduce unfavorable atomic clashes and geometric distortions.
In the panel, select the force field to be applied.
Recommended setting:
OPLS4
In older Maestro versions, OPLS3e or OPLS_2005 may also be available.
Throughout the remainder of this tutorial, the use of the OPLS4 force field is assumed.
To start the process, click the:
Run
button.
Once the calculation has finished, a prepared nucleic acid structure appears in the Entries panel, which can be used in the next step of the Desmond System Builder workflow.
Desmond System Builder
The prepared DNA aptamer alone is not yet suitable for molecular dynamics simulations. The biomolecule must be placed into a periodic simulation box containing solvent molecules and the appropriate counterions.
To build the simulation system, use the Desmond System Builder module.
The module can be launched from the following menu:
Applications
└── Desmond
└── System Builder
In the System Builder window, first select the previously prepared 1RDE structure.
Solvent Model Selection
For most biomolecular simulations, the use of an explicit aqueous environment is an appropriate choice.
In this tutorial, we use the SPC water model.
In the Solvation section, set:
Solvent:
SPC
This is the default water model used by Desmond. It is computationally efficient and widely applied in biomolecular simulations.
Defining the Simulation Box
The biomolecule must be placed in a simulation box with periodic boundary conditions.
For the Box Shape option, select:
Orthorhombic
It is generally advisable to maintain a minimum distance of 10 Å between the biomolecule and the box walls.
In the Box Size panel, set:
Buffer Width:
10.0 Å
Maestro will automatically generate a simulation cell of appropriate size and fill it with water molecules.
Note
A simulation box that is too small may result in artificial interactions between the molecule and its own periodic images.
Creating the Ionic Environment
The phosphate groups of DNA carry negative charges; therefore, the overall charge of the system will be negative.
For physical realism and proper treatment of electrostatic interactions using Ewald-based methods, it is recommended to electrically neutralize the system.
In the Ions panel, select:
Neutralize System
The program will automatically add the required number of counterions.
If physiological salt conditions are to be modeled, an additional salt concentration may also be specified.
For example:
Add Salt:
0.15 M NaCl
In this example, however, simple neutralization of the system is sufficient.
Force Field Selection
In the Force Field panel, select the OPLS4 force field (or another force field of your choice).
System Building
After verifying the settings, click the:
Build
button.
Building the system may take anywhere from a few seconds to several minutes depending on the size of the molecule.
Once the process is complete, a new entry appears in the Entries panel, which now contains:
the DNA aptamer;
water molecules;
the added ions;
the periodic simulation cell.
The simulation box can also be displayed in the Workspace window.
Solvated system generated by the System Builder.
The generated system is now ready for the relaxation protocol, which removes unfavorable initial interactions and prepares the system for the production molecular dynamics simulation.
System Relaxation
The system generated by the System Builder is not yet suitable for a long molecular dynamics simulation. The initial arrangement of water molecules and ions may result in energetically unfavorable interactions that can distort the early stage of the simulation.
Therefore, the system should first be relaxed.
To start the relaxation protocol, select:
Applications
└── Desmond
└── Molecular Dynamics
In the Molecular Dynamics panel that appears, select the system generated by the System Builder.
In the Simulation Settings section, the predefined relaxation protocol can be used:
Task:
Relax Model System
This automated protocol provided by Desmond consists of several consecutive stages:
Energy minimization
Short NVT simulation
Gradual heating
NPT equilibration
During the relaxation procedure, the biomolecular structure is initially restrained by positional constraints, while the solvent and ions are free to reorganize around it.
To start the calculation, click the:
Run
button.
After the run is completed, a new system is generated that can be used as a stabilized starting structure for the production simulation.
Note
The relaxation stage typically completes within a few minutes, whereas the production simulation may require significantly longer computational time.
Applying Restraints During Relaxation
For certain systems, significant conformational changes may occur during the initial relaxation stage. This is particularly common for nucleic acids, G-quadruplexes, or NMR-derived structures that do not represent an energy minimum.
During relaxation, the planar character of the guanine tetrads was lost.
To prevent undesired structural rearrangements, Desmond provides support for applying various types of geometric restraints.
The purpose of these restraints is not to artificially fix the structure throughout the entire simulation, but rather to facilitate a controlled relaxation of the system.
Positional Restraints
The most commonly used approach is the application of positional restraints.
In this case, a harmonic potential is applied to the selected atoms, keeping them close to their initial positions.
To add a restraint, open the Molecular Dynamics panel:
Applications
└── Desmond
└── Molecular Dynamics
Then, in the Simulations window, select:
Restraints
└── Add Restraint...
In the dialog window, the atoms to which the restraint will be applied can be selected.
For the example calculation, a force constant of 5.0 kcal mol^-1 Å^-2 is applied to eight carbon atoms.
The restraint strength typically falls within the range:
1.0 - 10.0 kcal mol^-1 Å^-2
Values significantly larger than this may overly restrict the natural motion of the system; therefore, it is advisable to begin with smaller force constants.
In our case, applying the restraint described above preserves the planar character of both guanine tetrads throughout the relaxation procedure.
A recommended strategy is to use restraints only during the relaxation stage.
This allows the solvent and ions to reorganize around the biomolecule while preserving the essential structural features of the initial conformation.
The purpose of the relaxation stage is to eliminate unfavorable initial structural contacts and to allow the solvent and ions to adopt an appropriate arrangement around the biomolecule.
Production Molecular Dynamics Simulation
Once the system has stabilized, the actual molecular dynamics simulation can be started. At this stage, we aim to investigate the natural motion of the system; therefore, any positional restraints applied previously are removed.
To configure the simulation, open the Molecular Dynamics panel again:
Applications
└── Desmond
└── Molecular Dynamics
Recommended settings:
Ensemble: NPT
Temperature: 300 K
Pressure: 1.01325 bar
Trajectory save: 100 ps/frame
Simulation time: 100 ns
In the Restraints section, verify that all previously defined
restraints have been removed.
After starting the simulation, Desmond automatically generates the trajectory files, which can later be used for various structural analyses.
Dynamics Analysis
Trajectory Analysis
After the simulation has finished, it is recommended to first assess the stability of the system. One of the simplest ways to do this is by visually inspecting the trajectory.
To open the trajectory, select the appropriate CMS and trajectory files, then start playback. Or you can click on the T sign in the Entries panel.
During visual inspection, it is particularly useful to monitor the following:
whether the guanine tetrads remain intact,
whether the central potassium ion remains stable,
whether significant structural distortions occur,
whether partial unfolding or structural rearrangements take place.
Visual analysis can often reveal structural changes that are not readily identifiable from averaged quantities alone.
RMSD Analysis
From the menu next to the trajectory playback controls, select:
Plot → Descriptors (selected atoms) → RMSD
This option allows RMSD calculations to be performed for the selected region (in our case, the entire TBA structure consisting of 350 atoms). The resulting plot shows the deviation relative to the first frame of the trajectory.
If you would like to verify the reference structure or inspect the set
of selected atoms used for the calculation, this can be done through
the View RMSD settings... window.
If the RMSD initially increases and subsequently fluctuates around a nearly constant value, the system can be considered properly equilibrated.
Hydrogen Bond Analysis
One of the most important indicators of G-quadruplex stability is the persistence of hydrogen bonds within the guanine tetrads.
To analyze hydrogen bonds, select the appropriate analysis tool and specify the donor and acceptor atoms.
The analysis can provide information such as:
the occurrence frequency of individual hydrogen bonds,
the average donor-acceptor distance,
the temporal evolution of the hydrogen bonds throughout the trajectory.
Hydrogen bonds with high occurrence frequencies can be considered key interactions contributing to the stabilization of the G-quadruplex structure.